CONNECTIONS
TECHNICAL DATA
TOUCHSCREEN USAGE
FACTORY DEFAULTS
BALANCER CONNECTION
P1 PROFILE NAME .
LINEAR CHARGE
SETUP START
Connection Example 3S: Connection Example 4S:
P1 CHARGE [1/2] X
Chg Mode : Linear
Current : 4.0A
DPeak : 20mV
Trickle : Off
Safety Time: 90min
SET
NEXT
P1 CHARGE [2/2] X
Cut-Temp : 55°C
SET
NEXT
_XXXX CHARGE 02m30s
Capacity 250mAh
Current 6.00A
Voltage 7.82V
Resistance 0.0m
Temperature 0.0°C
_XXXX CHARGE 02m30s
Capacity 250mAh
Current 6.00A
Voltage 7.82V
Resistance 0.0m
Temperature 0.0°C
NEXT
STOP
P1 PROFILE NAME
X
ABCDEFHIJKLMNOP
QR
STUVWXYZabcdefg
hi
jklmnopqrstuvw
xyz
0123456789-._
#+/
DEL
V
OK
P1 PROFILE NAME .
LINEAR CHARGE
SETUP START
_XXXX CHARGE 02m30s
Capacity 250mAh
Current 6.00A
Voltage 7.98V
Resistance 0.0m
Temperature 0.0°C
STOP
NEXT
Dear Customer,
thank you for your trust in this LRP product. By purchasing a LRP Pulsar Touch, you have chosen a high-performance product
which has the latest technology incorporated including the following High-Tech features:
• Professional Multi-Function System (Charge, Discharge, Cycle, Balance, Motor/ESC/Servo Check)
• up to 12.0A Charge Current • up to 20.0A discharge current (+ 35A Pulse Discharge)
• LiPo • LiFePo • NiMH • NiCd • Integrated Balancer for 2S-4S Lixx batteries
• Touchscreen Graphics LCD Display • 5 User Profile Memories
• 25-Year Warranty • Multi-Protection-System
Please read the following instructions carefully before you start using your charger. This user guide contains important
notes for the installation, the safety, the use and the maintenance of this product. Thus protecting yourself and avoid
damages of the product.
Proceed according to the user guide in order to understand your charger better. Please take your time as you will have much
more joy with your product if you know it exactly.
This user manual shall be kept in a safe place. If another customer is using this product, this manual has to be handed out
together with it.
LA00048
USER GUIDE - #41555
LRP electronic GmbH
Wilhelm-Enssle-Str. 132-134
73630 Remshalden, Germany
info@LRP.cc www.LRP.cc
© LRP electronic GmbH 2010
Dimensions
[mm]
1585x172x68 Autostart Timer yes, 0-99min
Weight
[g]
720
Cycle Mode
yes, adjustable
Input Voltage [DC]
11-15V
User Profile Memory
5
Charging Capability
LiPo/LiFePo
1 - 4 cells Graphical Touchscreen LCD yes, blue backlit
NiMH/NiCd
1 - 10cells
Acoustic Signal Type
Buzzer
Charge Current
[A]
0.1 - 12.0 Finish Melody adjustable
Trickle Current
[A]
0 -0.55
Multi-Protection-System
yes
Delta Peak
[mV]
1 - 200 DC Input Connection 4.0mm connector
Integrated High-Performance Balancer yes, 2S - 4S Output Connection 4.0mm jacket
Storage Charge Mode yes Brushless Motor Sensor Port yes
Discharge Current
[A]
0.1 -20.0 (+ 35 Pulse) RX Generator (ESC + Servo Check) yes
Discharge
Cut-Off Voltage
LiPo/LiFePo
2.0 - 4.2V/cell Voltage Calibration Mode yes
NiMH/NiCd
0.1- 1.3V/cell USB Connection yes
Specifications subject to change without notice.
Output Jacket: connect battery to be charged to the
4.0mm jacket, using supplied charge wires.
Caution: Be careful with correct polarity!
Balancer Connector: high-performance integra-
ted Lixx balancer for 2S to 4S packs using EHR balancing
connector.
The Pulsar Touch comes with 5 pre-set user profiles, but you can also alter those and prepare 5 individual user profiles and
even name them as you like. This means you can customize 5 personal charge profiles individually and store them for later
use. The active profile P1 to P5 and it‘s name is indicated in the headline of the main menu.
User Profile P1 P2 P3 P4 P5
CHARGE SETTINGS:
Chg Mode LiPo LiFe LiPo LiPo Linear
Current 6.0A 6.0A 6.0A 2.0A 4.0A
Pack Volt 7.4V / 2S 6.6V / 2S 3.7V / 1S 11.1V / 3S
D-Peak 20mV
Trickle Off
Safety Time 120min 120min 120min 180min 90min
40°C 40°C 40°C 40°C 55°C
DISCHARGE SETTINGS:
Current 20.0A 20.0A 20.0A 2.0A 10.0A
Pack Volt 7.4V / 2S 6.6V / 2S 3.7V / 1S 11.1V / 3S
Cutoff Volt 3.2V/C 2.2V/C 3.2V/C 3.2V/C 5.4V
Cut-Temp 60°C 60°C 60°C 60°C 70°C
OTHER SETTINGS:
Profile Name 2S-LiPo 6A/20A 2S-LiFe 6A/20A 1S-LiPo 6A/20A 3S-LiPo 2A/2A Linear 4A/10A
Signal Min 1000
Signal Max 2000
Button Sound On
Finish Sound 15sec
Finish Melody 1
LCD Contrast 7
Temp Scale °C
The Pulsar Touch contains an integrated competition balancer for 2S to 4S LiPo- and LiFePo-batteries using EHR balancing
connector. Please refer to drawing (also like that on charger) for correct polarity, basically minus (black wire) is always on the
far right side of the plug as shown on drawing.
The balancer equalises the cells, during charge- and balance-function, which results in higher performance and higher cycle-
life.
Caution: Avoid incorrect connection as in the worst case this may result in damage to the battery and/or charger!
As known from LRP, the programme structure is logical and intuitive, therefore most users can familiarise with the usage and
functions without even reading the manual, but it is obviously strongly recommended to read this manual in order to achieve
maximum performance from the PulsarTouch and make best use of all of it‘s great features.
You can either use your finger or the included plastic pen to use the touchscreen, make sure you only use very light pressure
to activate the functions as too high pressure may damage the display!
How to change the profile names?
Keep headline pressed in main menu, this brings you into the function to alter the active profiles name.
press arrow to scroll to the
„right“ (e.g. next function)
press arrow to scroll to
the „leftt“ (e.g. previ-
ous function)
Press briefly to jump to next profile (P1 > P2 > P3 > P4 > P5 > P1 ...).
Keep pressed to enter „Profile Name“ menu, which allows renaming of the choosen profile (see below).
press „SETUP“ to change the settings of
this function (in this case the function is
LINEAR CHARGE).
The logo (LINEAR CHARGE in this case) indicates
which function is pre-selected.
Press „START“ or center symbol to start the function.
Temperature Sensor (optional): connect the
optional temperature probe to measure battery tempe-
rature.
USB Connection: connect to PCB using the sup-
plied USB-cable. To be used for upcoming firmware
updates and PC software.
Brushless Motor Sensor Port: a fantastic fea-
ture which allows you to check your brushless motors
sensors and even measure motor rpm! In combination
with the built-in receiver simulator port.
RX Simulator Port: you can even check speed-
controls and servo‘s for correct function!
15A Fuse: input fuse for protection, only replace with ano-
ther 15A fuse (blue colored housing) and no other types as
these would not offer protection or correct function!
Connection Example 2S:
Black
Minus
Adjusting the settings and hoping through multi-page menu:
Hidden buttons and how to make them visible again?
To allow more clean screen and more useful information, the buttons will be hidden during many active functions. Simply
touching the screen anywhere will make the buttons visible again. After a short while of no use of the screen, the buttons
will hide again automatically.
Buttons Hidden: Buttons visible again (after briefly touching screen anywhere):
as [1/2] and [2/2] indicate
in headline, there is a multi-
page menu with more then
one screen. You can hop
through the pages by pres-
sing „NEXT“ button.
after accessing the menu with SE-
TUP“ you can select the value which
you may access that value directly
by pressing with your finger or pen
or by pressing „SET“ button.
Once this line is shown inversed
(black background), you can then
change that value using the up/down
arrown keys.
You may leave the „SETUP“ menu
again at any time, and the current
values will be stored, by pressing X
in upper/right corner
Tip: You can always reset to above factory default settings under „CONFIG“ function (see separate box).
indicates which
character in head-
line you have se-
lected for changing
You can change the name in several ways, pick the method you feel most
comfortable with.
1. straight indicate/write by touching the characters one after the other.
2. hop through the characters by using the right key and confirm the se-
lected character by using the „√“ key.
You confirm and leave this setting by either pressing „X“ symbol in upper
right corner or by pressing „OK“ key.
indicates new character
you have selected.
How to adjust the current on the fly?
As known by LRP, the Pulsar Touch‘s current (charge or discharge) can be adjusted during use. Touch the current value on
the screen, the characters will become inverse (black background) and then use the up/down arrow keys to adjust the current
to your desired value without interrupting the active process.
Important: This change is not saved in memory, the next time you use this function the settings from the memory will be
used.
Touch current, characters will be-
come inverse (black background)-
Now use up/down arrow keys
to adjust current to your desired
value.
Black
Minus
Black
Minus
Cell 1
Cell 1
Cell 1
Cell 2
Cell 2
Cell 2
Cell 3
Cell 3
Cell 4
Input Connection (backside of charger, no picture): connect your Pulsar Touch to a suitable DC powersupply with
11-15V output voltage and a minimum of 12.0A output current. Caution: Be careful with correct polarity!
Page view 0
1 2 3 4

Summary of Contents

Page 1 - USER GUIDE - #41555

CONNECTIONSTECHNICAL DATATOUCHSCREEN USAGEFACTORY DEFAULTSBALANCER CONNECTION P1 PROFILE NAME . LINEAR CHARGE SETUP START Connecti

Page 2 - VIEW LAST DATA

CHARGE PROCESSPROGRAMME STRUCTURE - SETUPVIEW LAST DATA P1 PROFILE NAME . LINEAR CHARGE SETUP START P1 PROFILE NAME .

Page 3 - DISCHARGE

CYCLEMOTOR - ESC - SERVO CHECKDISCHARGEBALANCE P1 PROFILE NAME . CYCLE SETUP START P1 PROFILE NAME . MOTOR-ESC-SER

Page 4 - RECOMMENDED CHARGE CURRENTS

CONFIG TOUCHSCREEN CALIBRATIONUSEFUL ACCESSORIESTROUBLESHOOTINGREPAIR PROCEDURES / LIMITED WARRANTYRECOMMENDED CHARGE CURRENTS P1 PROFILE NAME .

Comments to this Manuals

No comments